FDA StandardsRequirements Class*1I IIa II IIIa IIIb IVPerformance (all laser products)Protective housing [1040.10(f)(1)]Safety interlock [1040.10 (f) (2)]Location of controls [1040.10(f)(7)]Viewing optics [1040.10(f)(8)]Scanning safeguard [1040.10(f)(9)]R *2R *3,4N/ARRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRR *2R *3,4RRRPerformance (laser system)Remote interlock connector [1040.10(f)(3)]Key control [1040.10(f)(4)]Emission indicator [1040.10(f)(5)]Beam attenuator [1040.10(f)(6)]Manual reset mechanism [1040.10(f)(10)]N/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/AN/ARRN/AN/AN/ARRN/ARRR *10RN/ARRR *10RR *13Performance (specific-purpose products)Medical [1040.11(a)]Surveying, leveling, alignment [1040.11(b)]Demonstration [1040.11(c)]SSSSSSSSSS*8SSS*8NPS*11S*8NPS*11Labeling (all laser products)Certification/identification [1010.2,3]Protective housings [1040.10(g)(6),(7)]Aperture [1040.10(g)(4)]Class warning [1040.10(g)(1),(2),(3)]RDN/AN/ARR *5N/AR *6RR *5RR *7RR *5RR *9RR *5RR *12RR *5RR *12Information (all laser products)User information [1040.10(h)(1)]Product literature [1040.10(h)(2)(i)]Service information [1040.10(h)(2)(ii)]RN/ARRRRRRRRRRRRRRRRR: RequiredN/A: Not applicableS: Requirements: Same as for other products of that Class.NP: Not permittedD: Depends on level of inner radiationRamco National800-280-6933 | nsales@ramcoi.comwww.panasonicsensors.com