2-5 Conditions When Output Data Become UnfixedThe operation status will be judged as a data unfixed status (i.e., there is no determineddata) immediately after settings changes are made, the system is reset, or laser stop inputis turned ON. This status is not an alarm status.The data unfixed status starts at the time of restarting measurement after settingrefreshment or resetting until the number of data measurement times reaches an average.Under the data unfixed status, a digital output of -999.9999 [mm] and an analogoutput of 11.000 [V] or 21.6 [mA] *1 will be turned ON.*1 This is the initial value. Under the data unfixed status, the analog output of thesystem can be changed to a fixed value. For more information, refer to“3-3-7 Alarm Settings” – “Analog Output at Alarm”.*2 Under the data unfixed status, the zero set input will be ignored.*3 For cancelling the data unfixed status, refer to Chapter 5 “Troubleshooting”.For example, the graph on the right-handside shows the digital display at reset inputfor NORMAL measurement.The table below shows the measurementvalue display and output under the dataunfixed status or alarm status.Data unfixed status Alarm statusStatusMeasurement data is unfixed.(Average buffer has not reachedthe setting number of times.)Measurement disabled status due topoor light intensity or when the targetobject is off the measurement range.MeasurementValue Display 「――――――」 The previous value (default) is kepton hold.Analog output The previous value (default) iskept on hold.The previous value (default) is kepton hold.Digital output(High function typeonly)-999.9999 [mm] The previous value (default) is kepton hold.JudgmentOutput LO judgment Interlocks with digital outputAlarm output Interlocks with alarm status ONReset inputData unfixed status(Data remeasurementperiod)Ramco National800-280-6933 | nsales@ramcoi.comwww.panasonicsensors.com