Value Range Max. 1000 charactersDefault Value Empty stringWeb User Interface Reference Dial Plan (max 1000 columns) (Page 147)DIAL_PLAN_NOT_MATCH_ENABLE_nParameter Name Example DIAL_PLAN_NOT_MATCH_ENABLE_1,DIAL_PLAN_NOT_MATCH_ENABLE_2, ...,DIAL_PLAN_NOT_MATCH_ENABLE_6Value Format BOOLEANDescription Specifies whether to enable dial plan filtering so that a call is not madewhen the dialed number does not match any of the dial formatsspecified in "DIAL_PLAN_n".Value Range • Y (Enable dial plan filtering)• N (Disable dial plan filtering)Note• If set to "Y", the dialed number will not be sent to the line whenthe number dialed by the user does not match any of the dialformats specified in the dial plan.• If set to "N", the dialed number will be sent to the line, even ifthe number dialed by the user does not match any of the dialformats specified in the dial plan.Default Value NWeb User Interface Reference Call Even If Dial Plan Does Not Match (Page 147)MACRODIGIT_TIMValue Format INTEGERDescription Specifies the length of time, in seconds, that the unit waits when a "T"or "t" has been entered in the dial plan.Value Range 1–15Default Value 5Web User Interface Reference Timer for Dial Plan (Page 138)INTERNATIONAL_ACCESS_CODEValue Format STRINGDescription Specifies the number to be shown in the place of the first "+" symbolwhen the phone number for incoming international calls contains "+".Document Version 2015-07 Administrator Guide 3035.3.34 Call Control Settings