19In most cases, you will not need to change the settings in the sys.ini file. However, if changes are necessary, the MPU955 CPUmust be rebooted.Text appearing in blue is explanatory, and not part of the sys.ini file.Interface sectionThe CPU can incorporate up to three Ethernet network interface cards.[INTERFACES]***{ Number of interfaces in the system}Numinterfaces=3The number used here is the number of the Ethernet ports on MPU955 CPU.***{ Interface Definitions }***{ Interface=,, }***{ !! Note: The InterfaceX IPAs must match the MainX CPU }***{ hardware settings in order for the System to }***{ operate correctly!!***{ MainA CPU }In a standalone system, the MPU955 CPU should use the IP addresses that follow. In this case, the {MainBCPU}’s interface numbers should be commented with asterisks.Interface0=192.168.200.200,255.255.255.0,192.168.200.200Interface0 is an interface for GX devices.Interface1=172.18.0.1,255.255.0.0,172.18.0.1Interface1 is an interface for system controller.Interface2=172.16.192.1,255.255.0.0,172.16.192.1Interface2 is used for SNMP, SNTP feature. (Not currently supported)***{ MainB CPU }In a redundant system, the second MPU955 CPU should use following IP addresses (remove the asterisksbelow). In this case, {MainA CPU}’s interface numbers should be commented with asterisks.*Interface0=192.168.200.201,255,255,255,0,192.168.200.201*Interface1=172.18.0.2,255.255.0.0,172.18.0.2*Interface2=172.16.192.2,255.255.0.0,172.16.192.2Frames section[CAUTION] This section does not apply to the MPU955 system, and should not be changed.[FRAMES]***{ MX Frame definition from Admin file }***{ MXSW has format ,, }***{ All others use , }***{ All 0's used for digital-only systems. }MXSWFunction=0,0,0MXCONTFunction=0,0MXOSDFunction=0,0MXDIOFunction=0,0MXRMSFunction=0,0Default SYS.INI Configuration