Compax3 device description Single axis devices24 192-120102 N16 December 20103.3.5. Compax3Sxxx V2In diesem Kapitel finden SieMain voltage supply C3S connector X1 ........................................................................... 24Braking resistor / high voltage DC C3S connector X2 ..................................................... 253.3.5.1 Main voltage supply C3S connector X1By cyclically switching on and off the power voltage, the input currentlimitation can be overloaded, which will cause a device error.Therefore please wait at least 2 minutes after switching off before you switchthe device on again!Power supply plug X1 for 1 AC 230VAC/240VAC devicesPIN Designation1 L2 N3 PEMains connection Compax3S0xxV2 1ACController type S025V2 S063V2Supply voltage Single phase 230VAC/240VAC80-253VAC / 50-60HzInput current 6Arms 13ArmsMaximum fuse rating per device(=short circuit rating)10 A (MCB miniaturecircuit breaker, Kcharacteristic)16A (automatic circuitbreaker K)* for UL conform operation, a miniature circuit breaker, K characteristic, Type S203is to be used.Caution - Risk of Electric Shock!Always switch devices off before wiring them!Dangerous voltages are still present until 10 min. after switching off the powersupply.Power supply plug X1 for 3AC 230VAC/240VAC devicesPIN Designation1 L12 L23 L34 PEMains connection Compax3S1xxV2 3ACController type S100V2 S150V2Supply voltage Three phase 3* 230VAC/240VAC80-253VAC / 50-60HzInput current 10Arms 13ArmsMaximum fuse rating per device(=short circuit rating)16A 20AMCB miniature circuit breaker, K characteristic* for UL conform operation, a miniature circuit breaker, K characteristic, Type S203is to be used.Device protection