554444 – RESET REPORTS AND COUNTERS1. Turn Lock to P2. Enter 4444 on the TYPE key3. The register will use now clear all reports, tables and reset the receipt and invoicecounters.4. It will print on the journal MESSAGE# 68 (SYSTEM CLEAR)5. Finished16. Contrast Setting at 16-line-displayVariant A from version XX0303071. PARAMETER 100 is used to set the contrast.2. Switch key lock to P-mode and enter 1 + TYPE + 100 + X.3. The contrast value can be set between 10 and 24, default is 17.4. If the entered value is zero or outside this range, the contrast is set back to default.5. When finished the contrast setting press the TYPE key or turn back the key lock.Variant B from version XX0305071. The contrast can now be adjusted directly with two keys in R-mode.2. Start contrast setting by entering 9999 on the SUBTOTAL key in R-Mode or on theTYPE key in P-mode. You can also create a MACRO key for this.3. The register will display the current value of Parameter 100 on the operator displayand fill the remaining with test strings.4. To increase the contrast, press the LINE UP or PAGE UP key and to decrease thecontrast press the LINE DOWN or PAGE DOWN key.5. The register will adjust the contrast by one step at a time. Note that after reachingthe minimum or maximum value the contrast is set back to default.6. When finished changing the contrast press the CLEAR key or turn the key lock.7. The contrast setting is only possible if all receipts are closed.1.50.417180 BA-englisch GB QMP3000 Quorion CE (Stand: 05.02.09)