8.3.15 Air TempThis value displays the board’s temperature in degrees Celsius.8.3.16 CPU Temp (Type B and C FCOs only)This value displays the CPU’s temperature in degrees Celsius.8.3.17 UPDATEThis menu item is visible when communications to the Fibre Channel Option is in anidle state. Invoking this command will cause the Fibre Channel Option to update theconfiguration and environmental information.It takes approximately 35 seconds to obtain new information after the UPDATE com-mand has been invoked.8.4 Maintenance\Fibre Channel\ Log (Left or Right) Status ScreenMFC..............LogMFC.........Log LeftMFC........Log RightThe Fibre Channel Log status screen displays the Fibre Channel Option’s internalevent log. The information is provided to assist in troubleshooting problems and is notrequired for normal library operation. The event log is saved in non-volatile memoryand is not lost when the library power is removed.The first line in the status screen indicates the Fibre Channel Option selected. Thesecond line contains the event sequence number and a timestamp. Lines three andfour contain event text description. If the second line ends with an up arrow, newerevents are available for viewing. If the last line ends with a down arrow, older eventsare available for viewing. These older or newer events can be viewed by using thes (UP) and t (DOWN) keys to scroll the display. Since the event data is stored in theFibre Channel Option, a small time delay occurs after each request to retrieve the in-formation for display.Event Sequence NumberTimestamp Month (1-12)Timestamp Day (1-31)Timestamp Year (1970-20xx)Timestamp Hour (0-23)Timestamp Minute (1-59)Event Text Description LineFigure 8-3 Log Status Screen Sample8-6 Maintenance Menu 501440 Rev. J