2. Menu Structure - 2.12 AES18 Config (1218 only)ZOMBIEs 12xx117Terminate CRIn the submenu item, the user defines whether messages to the serial interface should beconcluded with a Carriage Return (CR).AES18 ConfigTerm. CR: OFFPulsar to the submenu item View TX AddressPulsar to the submenu item View TX ParameterExit back to the main menu item AES18 ConfigEnter to the submenu item Set Terminate CRToggle no operationENTER causes an arrow to appear after the colon. The user arrives at the submenu item SetTermiate CR.AES18 ConfigTerm. CR:> OFFPulsar switch on CRPulsar switch off CRExit back to the submenu item View Terminate CREnter back to the submenu item View Terminate CRToggle no operationTurning the pulsar or enables the user to determine whether the last data byte of eachmessage should be followed by a carriage return for synchronization purposes or not.EXIT discards the selection, and returns the user to the submenu item View Terminate CR.ENTER saves the selection, and also returns the user to the submenu item View TerminateCR.Note: When CR is turned on, a message may contain ASCII data only- i.e. values between 0x20 and0x7F. The command bytes, e.g. the length of the message, target address etc. are not affected bythis.