QL-800 Maintenance UtilityQL-800 User Guide 77Replacing the Maintenance CartridgeWhen the maintenance cartridge is filled to capacity with collected ink, printing stops. An errormessage and LED indicate this condition.• A message indicating the maintenance cartridge is full will be displayed in the StatusMonitor and System Logs tab of the Maintenance Utility.• The non-ink consumables LED will illuminate (solid).Use the following procedure to replace the maintenance cartridge.Note: For safety, keep the maintenance cartridge out of the reach of children. If ink isaccidentally ingested, contact a physician immediately.• To prevent ink from leaking from a used maintenance cartridge, avoid dropping thecartridge or storing it at an angle. Otherwise, ink may leak and cause stains.• Ink adheres to the maintenance cartridge after it has been used. Handle the maintenancecartridge carefully during replacement. The ink may stain clothing.Note: Wear protective gloves to prevent ink from staining your hands during this procedure.1 Launch the QL-800 Maintenance Utility.From the Windows Start Menu, choose Start > All Programs > QuickLabel QL-800 >QL-800 Maintenance Utility. A language and printer prompt will open.Select a display language and the QL-800 printer you want to connect to. Choose OK.2 Choose the Parts Replacement tab.3 Select Maintenance Cartridge. Then choose Start. Follow the on-screen instructions tocomplete this procedure.