ESP-SMTe Controller17Fine-Tune WateringAdjust the calculated run time for each zone.Turn the dial to Fine-Tune Watering.A Press BACK or NEXT to select the zone to adjust.B Press – or + to set the adjustment percentage for theselected zone.C After making any adjustments, return the dial toAUTO RUN.If minor adjustments are required to calculated run times,you can increase or decrease run times for ET zones by aselected percentage. These adjustments will apply untilyou set the value back to 0.The Fine Tune % By Zone value can be adjusted from -60%to +60%. For example, if a +50% adjustment is set, then acalculated run time of 10 minutes will become 15 minutes.cb NOTE: Fine-Tune Watering adjustments always applyto all zones in Simple Mode.cb NOTE: Fine Tune settings can be adjusted for NewlyPlanted zones, but will not take effect until the NewlyPlanted mode expires.System ReviewView system settings and weather information.cb NOTE: The information under System Review is forreview purposes only. This allows the review of pro-gramming settings without accidentally makingunwanted changes.Turn the dial to System Review.Controller SettingsReview Configure Controller settings.A Select Controller Settings.B Review location data and delay settings; then pressMORE.C Review Program A; then press MORE.D Review Program B then press MORE.Zone SettingsReview Input Zone Information and Advanced Zone Setupsettings.A Select Zone Settings.