Maintenance and repairC190AXISAXIS 50.2C.6 Checking the drop pointBy altering the drop point, the working width can be accurately set and adjust-ments to different fertiliser types can be made.Check the setting of the drop point at the start of each working season, and duringthe season if necessary (if uneven spreading is noticed).NOTICEThe drop point must be set to the same position on both sides. Therefore, al-ways check both settings.1. AXIS 50.2 D: Manually setthe drop point to position 6.AXIS 50.2 W: Set the droppoint with the QUANTRONcontrol unit to position 6.2. Switch off the electronic sys-tem.Figure 27: Setting the drop point to posi-tion 6.n WARNINGDanger of crushing and shearing due to components operat-ed by an external forceWhen working on power-operated components (adjusting lever,metering slides), there is a crushing and shearing risk.Pay attention to the shear point of the metering slide opening andthe metering slide during all adjustment work. Switch the tractor motor off. Remove the ignition key. Disconnect the power supply between the tractor and themachine. Never actuate the hydraulic metering slide during adjust-ment work.KDCQWR