MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC103 8540780 • 23/03/2017 • Rev.31* Simultaneity error = the maximum time between switching of thesingle contacts has been exceeded.ParametersManual Reset: If selected, enables the reset request after each activation of the device.Otherwise, enabling of the output follows directly the conditions of the inputs. Reset maybe of two types: Manual and Monitored. Selecting the Manual option, only transition ofthe signal from 0 to 1 is checked. If Monitored is selected, double transition from 0 to 1and return to 0 is checked.t = 250ms t1 > 250mst2 = 250ms WARNING: if Reset is enabled, the input consecutive to those used by the functionalblock must be used. For example: If inputs 1 and 2 are used for the functionalblock, input 3 must be used for Reset.Power-on test: If selected, enables the power-on test of the device. This test requiresactivation and de-activation of the device in order to run a complete functional check andenable the Output terminal. This test is required only at machine start-up (power-on ofthe module).Filter (ms): Permits filtering of signals from the device. This filter can be set to between 3and 250 ms and eliminates any rebounds on the contacts. The duration of the filteraffects calculation of module total response time.With simultaneity: If selected, activates control of simultaneity between switching ofsignals from the device.Simultaneity (ms): Is active only if the previous parameter is enabled. Determines themaximum permissible time (msec) between switching of two different signals from thesensor.Enable Error Out: If selected reports a fault detected by the function block.Item description: Permits insertion of a descriptive text of the function of the component.This text will be displayed in the top part of the symbol.SOLID STATE DEVICEThe SOLID STATE DEVICE functional block checksthe status of the Inx inputs. If the inputs are at24VDC, the Output will be 1 (TRUE), otherwise theOUTPUT will be 0 (FALSE).ParametersManual Reset: If selected, enables the reset requestafter each safety function activaction. Otherwise,enabling of the output follows directly the