MODULAR SAFETY INTEGRATED CONTROLLER MOSAIC16 8540780 • 23/03/2017 • Rev.31Englishswitch on the MOSAIC system, that will immediately load the backup configuration. In thisway, the work interruptions will be minimized. The LOAD and RESTORE functions can be disabled via SW. (see Figure 42) In order to be used, the expansion units must be addressed at the time ofinstallation (see the NODE SEL section). Each time MCM is used, carefully check that the chosen configuration is the one thatwas planned for that particular system. Try again a fully functional test of the systemcomposed of Mosaic plus all devices connected to it (see the TESTING the systemsection).Module MI8O2TERMINAL SIGNAL TYPE DESCRIPTION OPERATION1 24VDC - 24VDC power supply -2 NODE_SEL0 Input Node selection Input ("type B" according to EN 61131-2 )3 NODE_SEL1 Input Input ("type B" according to EN 61131-2 )4 0VDC - 0VDC power supply -5 OSSD1_A Output Static output 1 PNP active high6 OSSD1_B Output PNP active high7 RESTART_FBK1 Input Feedback/Restart 1 Input according to EN 61131-28 OUT_STATUS1 Output Programmable signal output PNP active high9 OSSD2_A Output Static output 2 PNP active high10 OSSD2_B Output PNP active high11 RESTART_FBK2 Input Feedback/Restart 2 Input according to EN 61131-212 OUT_STATUS2 Output Programmable signal output PNP active high13 OUT_TEST1 Output Short circuit detected output PNP active high14 OUT_TEST2 Output Short circuit detected output PNP active high15 OUT_TEST3 Output Short circuit detected output PNP active high16 OUT_TEST4 Output Short circuit detected output PNP active high17 INPUT1 Input Digital input 1 Input according to EN 61131-218 INPUT2 Input Digital input 2 Input according to EN 61131-219 INPUT3 Input Digital input 3 Input according to EN 61131-220 INPUT4 Input Digital input 4 Input according to EN 61131-221 INPUT5 Input Digital input 5 Input according to EN 61131-222 INPUT6 Input Digital input 6 Input according to EN 61131-223 INPUT7 Input Digital input 7 Input according to EN 61131-224 INPUT8 Input Digital input 8 Input according to EN 61131-2Table 2