P36E-4 Zero Clearance Direct Vent Gas Fireplace48WIRING DIAGRAMSThis heater does not require a 120V A.C. supply for operation. In case of a power failure, the burner switch and the optional remote control/thermostat will continue to operate. However, a 120V A.C. power supply is needed for the fan/blower operation.(Do not cut the ground terminal off under any circumstances.)NOTE: Even if the fan is not purchased with the unit, it is still a good idea to bring power to the receptacle box (provided with the unit)in case the fan is installed at a later date.Proflame SystemConfiguration886 GTMFWire DiagramINSTALLATIONSureFire™ SwitchProflame System886 ON/OFF Stand AloneIllustrated Wire DiagramSurefire Switch(IPI / CPI)Standard Main ON/OFFSwitch or Optional Wall SwitchBattery HolderPilot Ground WireChassis GroundEI PilotSense ElectrodeSpark ElectrodeDFC Wire Harness AssemblyProflame DFC Board886 Proflame ValveNote: 4 AA batteries must beinstalled to operate the burnerswitch.Do not use a 9 volt battery.IMPORTANT: If the optional remote control is used, the AA batteries normally installed into the battery holder must be removed. The AA batteries in thereceiver now operate the unit. Having AA batteries in both the battery holder and receiver will damage the gas valve.