P36E-4 Zero Clearance Direct Vent Gas Fireplace6This is a copy of the label that accompanieseach P36E Zero Clearance Direct VentGas Fireplace. We have printed a copyof the contents here for your review. Thesafety label is located on the front insidebase of the unit, visible when the bottomlouver is open.NOTE: FPI units are constantly beingimproved. Check the label on the unit andif there is a difference, the label on the unitis the correct one.SAFETY LABELDO NOT REMOVE THIS LABEL / NE PAS ENLEVER CETTE ÉTIQUETTE360360DOOR SEAL: Pleasecheck that the door isproperly sealedMinimum Clearances to Combustibles /Degagement Minimum De Materiaux CombustiblesSerial No./ No de serie918-853The "Bay Louvers" beused with the Bay Glass optionMUSTMAY BE INSTALLED IN MANUFACTURED (MOBILE) HOMES AFTER FIRST SALE.Duplicate S/NB B32"CeilingWallWall A0" Clearance tocombustibles from:Mantel Clearances from Top:Side Wall Clearancefrom Side FacingAlcove Clearances:Minimum Vent Clearances:Top, sides, bottom and rear of unit(A) Min. 7" (177mm)B) 6" with Flush or Bay FrontB) 8" with Barcelona TrimAlcove approved forBay & Flush Louvers.Max. Depth 36" (914mm)Min. Width 48" (1219mm),Min. Height 72" (1229mm)Vertical Vent 1-1/4" (32mm)Horizontal Top 2" (51mm)Horizontal Side 1-1/2" (38mm)Horizontal Bottom 1-1/2" (38mm)(See Instruction Manual for detailed instructions)É ÉQUIP A L'UISINE POUR GAZ PROPANEPROPANE GAS: Model P36E-LP411” WC/C.E. (2.73 kPa)10" WC/C.E. (2.49 kPa)6.4" WC/C.E. (1.59 kPa)Minimum supply pressureManifold pressure HighManifold pressure LowPression d'allimentation minimumPression la tubulure d' chappement lev ePression la tubulure d' chappement basseà é é éà é28,500 Btu for altitude 0 - 4500 ft.Maximum InputMinimum InputOrifice sizeAltitude28,500 Btu/h (8.35 Kw/h)22,000 Btu/h (6.44 Kw/h)#52 DMS0-4500 ft/pi (0-1372m)D bit Calorifique maximumD bit Calorifique minimumDimensions de l'orificeL'altitudeééMinimum supply pressureManifold pressure highManifold pressure lowOrifice sizeMinimum inputMaximum inputAltitudeNATURAL GAS: Model P36E-NG4 APPAREIL FONCTIONNANT AU NATURAL GASCONCU POUR ETRE POELE: Mod le P36E-NG4Pression d'allimentation minimumPression à la tubulure d' chappement lev ePression à la tubulure d' chappement basseGrandeur de l'injecteurD bit minimum selonD bit maximum selonl'altitudeCalorifiqueCalorifiqueéé é éééé5” (1.25kPa)3.5" (0..87kPa)1.6" (0.27kPa)#37 DMS0-4500 ft/pi (0-1372 m)WC/C.E.WC/C.E.WC/C.E.19,500 Btu/h (5.71 kW)29,500 Btu/h (8.65 kW)This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1, or Natural Gas and Propane Installation Code, CSA B149.1.This appliance must be installed in accordance with the Standard CAN/CSA Z240 MH, Mobile Housing, in Canada, or with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, in the UnitedStates, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations StandardThis appliance is only for use with the type of gas indicated on the rating plate and may be installed in an aftermarket, permanently located, manufactured (mobile) home where not prohibited by local codes. See owner's manualfor details. LP Conversion Kit #514-972Installer l'appareil selon les codes ou règlements locaux, ou, en l'absence de tels règlements, selon les codes d'installation ANSI Z223.1, National Fuel Gas Code ou CSA-B149.1 en vigueur.Installer l'appareil selon la norme CAN/CSA-Z240, Série MM, Maison mobiles ou CAN/CSA-Z240 VC, Véhicules de camping, ou la norme 24 CFR Part 3280, Manufactured Home Construction and Safety Standard. Si cesnormes ne sont pas pertinentes, utilisez la norme ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installations Standard.For use with glass doors certified with the appliance onlyThis vented gas fireplace heater is not for use with air filters. Ne pas utiliser de filtre à air avec ce foyer au gaz à évacuation.Fan (Part # 432-917) Optional Bay Window (Part #510-930) Option: HeatWave Kit # 946-556Electrical supply / Électrique 115VAC, 1.13 A, 60Hz.Cet appareil doit être utilize uniquement avec le type de gaz indiqué sur la plaque signalétique. Cet appareil peut être installé dans une maison préfabriquée ou mobile (É.-U. seulement) installée à demeure si les règlementslocaux le permettent. Voir la notice de l'utilisateur pour plus de renseignements. Cet appareil ne peut pas être utilisé avec d'autres gaz sauf si une trousse de conversion certifiée est fournie.Pour utilisation uniquement avec les portes en verre certifiées avec l'appareilMade in Canada/Fabrique au CanadaFPI Fireplace Products International Ltd.Delta, BC, CanadaListed:Certified for/Certifi e pour:Tested to:WN# 16546CANADA and U.S.A.CAN/CGA-2.17-M91, ANSI Z21.88-2009 / CSA 2.33-2009VENTED GAS FIREPLACE HEATER / FOYER AU GAZ À ÉVACUATIONéVENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUELS.NE PAS UTILISER AVEC DUCOMBUSTIBLE SOLIDE.FOYER AU GAZ À ÉVACUATION -For the State of Massachusetts, installationand repair must be done by a plumber orgasfitter licensed in the Commonwealth ofMassachusetts.For the State of Massachusetts, flexibleconnectors shall not exceed 36 inches inlength.For the State of Massachusetts, the appli-ances individual manual shut-off must be at-handle type valve.The State of Massachusetts requires theinstallation of a carbon monoxide alarm inaccordance with NFPA 720 and a CO alarmwith battery back up in the same room wherethe gas appliance is installed.