Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace 37INSTALLATIONCan be used with Option 1 or 3but not both.1) Run the supplied 15' of wire through theback gas inlet opening. Be careful not todamage wire.Note: We recommend a maximum of 15'of wire but if you wish to go with alonger run, use the Thermostat WireTable.2) Connect the wire to the supplied wall switchand install into the receptacle box.CAUTIONDo not connect millivoltwall switch wire to a 120V wire.14 GA.16 GA.18 GA.20 GA.22 GA.50 Ft.32 Ft.20 Ft.12 Ft.9 Ft.Recommended Maximum Lead Length(Two-Wire) When Using WallThermostat (CP-2 System)Wire Size Max. LengthThermostat Wire TableOPTIONALWALL THERMOSTATCan be used with Option 1 or 2but not both.A wall thermostat may be installed if desired,connect the wires as per the wiring diagram in"Wiring Diagram" section. Use the table belowto determine the maximum wire length.Note: Preferable if the thermostat is installedon an interior wall.Regency ® offers an optional programmablethermostat but any 250-750 millivolt rated non-anticipator type thermostat that is CSA, ULC orUL approved may be used.CAUTIONDo not connect millivoltwall thermostat wiresto a 120V wire.Can be used with Option 2 or 3but not both.Use the Regency® Remote Control Kit approvedfor this unit. Use of other systems may voidyour warranty.The remote control kit comes with a hand heldtransmitter, a receiver and a wall mountingplate.1) Choose a convenient location on the wallto install the receiver and the receptaclebox (protection from extreme heat is veryimportant). Run wires from the fireplaceto that location. Use the Thermostat WireTable.2) Connect the two wires to the gas valve. Seediagram.CAUTIONDo not connect millivoltremote control wires to a120V wire.3) Install 3 AAA alkaline batteries in transmitterand 4 AA alkaline batteries in the receiver.Install the receiver and its cover in the wall.Switch the remote receiver to "remote"mode. The remote control is now ready foroperation.OPTIONALREMOTE CONTROLOPTIONALWALL SWITCH