Regency® P48-2 Zero Clearance Direct Vent Gas Fireplace 45MAINTENANCE6) Remove the burner by removing the screwon the left side and then slide the burner tothe left and lift out.7) Remove the right and left side deflectors byremoving the 2 screws on each deflector.REMOVING VALVE1) Shut off the gas supply.2) Remove the louvers (and bay door if it hasbeen installed).3) Open the flush door and remove the door.4) Remove the logs and side brick panels, ifinstalled.5) Remove the grate by lifting up and out.8) Remove the base brick panels.9) Disconnect the inlet gas line.10) Remove the 10 Phillips head screws securingthe valve tray assembly in place and thenlift the entire assembly out.Slide the burner to the left and lift out.GrateRemove the screw on the leftside of the burner.Right SideDeflectorLeft SideDeflector11) Disconnect the 2 TP wires and the 2 THwires from the valve.12) Undo the pilot tube from the valve with a7/16" wrench.13) Undo the quick drop out thermocouple nuton the valve with a 9mm (metric) wrench.14) Remove the Piezo igniter wire and pushbutton assembly.Valve TrayAssemblyLift entire valve trayassembly out.15) Undo the "gas out" flare nut with a 13/16"wrench.16) Undo the "gas out" flare fitting with an 11/16"wrench.17) Remove the 4 Phillips head screws fromthe sides of the valve bracket and removevalve.Hint: If you are using black pipe, ensurethat there is a union by the valve,otherwise removal will be almostimpossible.ThermopileWireThermocoupleWire Pilot Nut