18 Regency U41-3 ULTIMATE Gas Fireplace InsertMAINTENANCECAUTION:Label all wires prior to disconnection when servicing controls.Wiring errors can cause improper and dangerous operation.IMPORTANTDisconnect power supplybefore servicingWARNING: Electrical GroundingInstructionsThis appliance is equipped with athree pronged (grounding) plugfor your protection against shockhazard and should be pluggeddirectly into a properly groundedthree-prong receptacle. Do notcut or remove the groundingprong from this plug.FAN MAINTENANCETo remove fan:1) Unplug or disconnect power source tostove.2) Remove all logs and the rear log support,then remove the 6 screws holding theaccess panel in place.3) Disconnect white wire from fan to powercord.4) Disconnect black wire from molex plug tothermodisc.5) Unplug wire harness on left rear side panel(from inside the stove).6) Disconnect green ground wire from fanbody.7) Lift fan off of the 2 pins, tip forward and pullthrough firebox opening.If your fan requires maintenance or replace-ment, access to the fan is through the accesspanel on the rear wall of the firebox. NOTE: theunit MUST NOT be operated without thefan access panel securely in place andcorrectly sealed.IMPORTANT: These fans do collect alot of dust from within your home.Ensure you maintain these fan mo-tors on a regular basis by vacuumingout the fan squirrel cages.Replacing fan:Reverse above steps. Hint for pushing fan downonto pins - rub a bit of dish soap on the grommetso it will slide more easily onto the pin. Check tomake sure the fan is seated properly on the pins- try to move the fan back and forth, there shouldbe no noise, if there is check that the grommetshaven't come loose.Caution: Ensure that the wires do nottouch a hot surface.