15© 2017 SafeLine and all the SafeLine products and accessories are copyrighted by law.4455310006E4455310006E4455310006E4455310006E4455310006E4455310006E4455310006E4455310006E445531000COPYRIGHT SAFELINE AB 2011WWW.SAFELINE.SE SL6 R1.12SPEAKERSPEAKERSPEAKERSL6+ v2.04 ENStart upLED 1LED 2LED 3ResetLED INDICATION FRONT PANELLED 1 indicates the power supply statusContinuous Green Mains power supply OK.Flashing Red (400/400 ms) Battery operated, with power to the emergency light.Continuous Red Battery operated, no power to the emergency light.LED 2 indicates active alarm and battery conditionLight Off No active alarm/battery OK.Rapidly Flashing Yellow (200/200 ms) Active alarm not reset.Flashing Red (400/400 ms) Battery check in progress.Continuous Red Battery test failure/no battery connected.LED 3 indicates the phone line’s statusFlashing Green (100/100 ms) Fire Mode activated.Flashing Green (400/400 ms) Call connection in progress.Slowly Flashing Green (200/4600 ms) Telephone line connected.GSM network OK.Continuous Green Call connected.Flashing Yellow (100/100 ms) Incoming call.Flashing Red (400/400 ms) No telephone line connected.Searching for GSM network.Continuous Red No SIM card (when using GSM).Reset buttonPress for 3 sec Show GSM signal strength (see table above).Press 3 times Start a self test (battery + bus initialization).Press Once Resets an active alarm. Aborts calls in progress.Press 5 sec - Release SL6+ turns off. NOTE! Refers to battery powered only!COLOUR CODE LED1 2 3GSM SIGNALSTRENGTH3 green = 100 %1 yellow, 2 green = 85 %2 yellow, 1 green = 70 %3 yellow = 55 %1 red, 2 yellow* = 30 %2 red, 1 yellow = 15 %3 red = 0 %*Minimum signal strength for using GSM Interface.