32© 2017 SafeLineandalltheSafeLineproductsandaccessoriesarecopyrightedbylaw.E123456!SL6+ v2.04 ENConfigurationAlarm Status Outputs• Relay will be activated when set time reached.• Relay will be deactivated when emergencycall ends.Battery Failure• Relay will be activated when the battery testhas failed.• Relay will be deactivated by pressing the resetbutton.Pictogram Yellow (only relay 1)• Relay will be activated when the alarm buttonis pressed (yellow pictogram).• Relay will be deactivated when the reset buttonis pressed or if alarm centre presses “5”.Pictogram Green (only relay 2)• Relay will be activated when the call isacknowledged (green pictogram).• Relay will be deactivated when the call isdisconnected.Activate with DTMF 8 (only relay 1)• Relay will be activated for 5 seconds whenDTMF “8” is pressed.Activate with DTMF 9 (only relay 2)• Relay will be activated for 5 seconds whenDTMF “9” is pressed.Manual Reset• Relay will be activated when set time reached.• Relay will be deactivated by pressing the resetbutton.Emergency Call Failure• Relay will be activated when the emergencycall falied after 12 attemts, ”Emergency CallFail”.System Failure• Relay will be activated when power (230 VAC)and PSTN/GSM net is OK.• Relay will be deactivated when power supplyis gone more then 15 min. or when there is noGSM-net.Emergency Bell• Relay will be activated when the emergencybell output is active.• Relay will be deactivated when the emergencybell output is deactivated.RELAY FUNCTIONSThis applies for SW 4.00 or later.(Functions for earlier versions,please contact the supportteam.)Relays 1 and 2 can be programmedindependently.