26EN SL6+ v.3.04ConfigurationParameter ListCONFIGURATION DATA CODE DATA COMMENTSEnter configuration mode 00Enter password * - - - - # Default = 0000Exit configuration mode *00*#ALARM CODES CODE DATA COMMENTSP100 ID code *01* - - - - - - - - # P100 is always 8 digitsCPC ID code *02* - - - - - - # CPC 6-8 digitsQ23 ID code *03* - - - - - - - - - - - - # Q23 is always 12 digitsTELEPHONE NUMBERS CODE DATA COMMENTS1st Phone number *11* - - - - - - - - - # Phone number to alarm receiver: 1-20digits.If calling through a switch board, delaytime can be set by adding asterisksbetween leading number of the switch-board and telephone number for thealarm call receiver.Each asterisk (*) is equal to one seconddelay.Example #1: *11*0**1234567#Example #2: *11*# deletes the phone no.2nd Phone number *12* - - - - - - - - - #3rd Phone number *13* - - - - - - - - - #4th Phone number *14* - - - - - - - - - #CALL TYPE CODE DATA COMMENTSCall type 1st number *21* - # Change the call type of the stored tele-phone numbers:0 = P1001 = VOICE (default)2 = Q233 = CPCChange this only if your alarm operatoruses any of the mentioned protocols.Call type 2nd number *22* - #Call type 3rd number *23* - #Call type 4th number *24* - #Call type LMS number *30* - # LMS (Lift Monitoring System) call type0 = P1003 = CPC (Only battery alarm)5 = SMS