33E123456EN SL6+ v.3.04ConfigurationAlarm status outputs• Relay will be activated when set time reached.• Relay will be deactivated when emergency call ends.Battery failure• Relay will be activated when the battery test has failed.• Relay will be deactivated by pressing the reset button.Pictogram yellow (only relay 1)• Relay will be activated when the alarm button is pressed(yellow pictogram).• Relay will be deactivated when the reset button is pressedor if alarm centre presses “5”.Pictogram green (only relay 2)• Relay will be activated when the call is acknowledged(green pictogram).• Relay will be deactivated when the call is disconnected.Activate with DTMF 8 (only relay 1)• Relay will be activated for 5 seconds when DTMF “8” ispressed.Activate with DTMF 9 (only relay 2)• Relay will be activated for 5 seconds when DTMF “9” ispressed.Manual reset• Relay will be activated when set time reached.Emergency call failure• Relay will be activated when the emergency call falied after12 attemts, ”Emergency Call Fail”.System failure• Relay will be activated when power (230 VAC) and PSTN/GSM net is OK.• Relay will be deactivated when power supply is gone morethen 15 min or when there is no GSM-net.Emergency bell• Relay will be activated when the emergency bell input isactive.• Relay will be deactivated when the emergency bell input isdeactivated.Relay FunctionsThis applies for SW 4.00 orlater. (Functions for earlierversions, please contact thesupport team.)Relays 1 and 2 can beprogrammed independently.