PLC-WK2500 Expand Serial Command Functional Specifications40 / 748.10.7 CF_BACKGND CommandCommand “CF_BACKGND_%1” [CR]%1“BLUE” -------------------- Select Blue Back“USER” ------------------- Select User“BLACK” ------------------ Select Black Back“UP” ----------------------- The same operation as pressing Up key or Left key“DN” ----------------------- The same operation as pressing Down key or Right keyDetailsSet Screen status for no signal.(Available only in the normal Power ON status)The status set by this command is stored in EEPROM and the setting remainseven after the power is turned to ALL OFF status.*When 1=”USER” is received, error code “101” is returned, in the case ofCapture non-practice.Acceptable “000” [CR]ResponseUnacceptable “Error Code” [CR]8.10.8 CF_DISP CommandCommand “CF_DISP_%1”[CR]%1“ON” ----------------------------- Select Display“OFF” --------------------------- Cancel Display“CNTDWNOFF” -------------- Count down OFF“UP” ----------------------- The same operation as pressing Up key or Left key“DN” ----------------------- The same operation as pressing Down key or Right keyDetailsSet / Cancel DisplayThe value set by this command is stored in EEPROM and its setting is effectiveeven after ALL is OFF.This command is available in normal Power ON status.Acceptable “000”[CR]ResponseUnacceptable “Error Code”[CR]