PLC-WK2500 Expand Serial Command Functional Specifications62 / 749.9 Lamp Status Read Command9.9.1 CR_LAMPREPL CommandCommand “CR_LAMPREPL”[CR]Details Get information of Lamp Replacement timeAcceptable “000_%1”[CR]%1“1Y” -------------------------- Over lamp replacement time“1N” -------------------------- Within lamp replacement time“1” means the number of lamps.(1 lamp model→ “1”)“Y”/”N” means if it has reached its replacement time or not.e.g. “1Y” -----------projector is 1 lamp model and Lamp is over itsreplacement timeResponseUnacceptable “Error Code”[CR]9.9.2 CR_LAMPH CommandCommand “CR_LAMPH”[CR]Details Get total running time of lamp by hour (h)*Actual running time, not corresponding valueAcceptable “000_%1”[CR]%1 “00000”~“99999”ResponseUnacceptable “Error Code”[CR]9.9.3 CR_LAMPCORRESPH CommandCommand “CR_LAMPCORRESPH”[CR]Details Get total running time of lamp by hour (h)* Corresponding value, not actual running timeAcceptable “000_%1”[CR]%1 “00000”~“99999”ResponseUnacceptable “Error Code”[CR]9.9.4 CR_LAMPMODE CommandCommand “CR_LAMPMODE”[CR]Details Get setting status of Lamp ModeAcceptable “000_%1”[CR]%1“HIGH” -------------------- Lamp Mode is High“NORMAL” -------------- Lamp Mode is Normal“ECO” --------------------- Lamp Mode is EcoResponseUnacceptable “Error Code”[CR]