PLC-WK2500 Expand Serial Command Functional Specifications61 / 749.8.5 CR_HPOS CommandCommand “CR_HPOS”[CR]Details Get setting status of Horizontal Position Store ModeAcceptable “000_%1”[CR]%1 “-15” ~ “015”ResponseUnacceptable “Error Code”[CR]9.8.6 CR_ KYSTNMODE CommandCommand “CR_KYSTNMODE”[CR]Details Get setting status of Keystone Store ModeAcceptable “000_%a”[CR]%a “STR” ---------------------- Store mode is “Store”“RST” ---------------------- Store mode is “Reset”ResponseUnacceptable “Error Code”[CR]9.8.7 CR_CEIL CommandCommand “CR_CEIL” [CR]Details Get setting status of CeilingAcceptable “000_%1”[CR]%1 “ON” ------------------------------ Ceiling is ON“OFF” ----------------------------- Ceiling is OFFResponseUnacceptable “Error Code” [CR]9.8.8 CR_REAR CommandCommand “CR_REAR” [CR]Details Get setting status of RearAcceptable “000_%1”[CR]%1 “ON” ------------------------------ Rear is ON“OFF” ----------------------------- Rear is OFFResponseUnacceptable “Error Code” [CR]9.8.9 CR_SCREENASPECT CommandCommand “CR_SCREENASPECT”[CR]Details Get setting status of Screen aspectAcceptable “000_%1”[CR]%1“43MODE” ------------------- 4:3 mode is selected“169MODE” ------------------ 16:9 mode is selected“1610MODE” ---------------- 16:10 mode is selectedResponseUnacceptable “Error Code” [CR]