PLC-WK2500 Expand Serial Command Functional Specifications67 / 74Details Get Power management setting statusAcceptable “000_%a”[CR]%a“OFF” -------------------------- Power Management is OFF“READY” ---------------------- Power Management is Ready“SHUTDOWN” ---- Power Management is set to Shut Down modeResponseUnacceptable “Error Code” [CR]9.11.10 CR_P-MANETIME CommandCommand “CR_P-MANETIME”[CR]Details Get time to start Power ManagementAcceptable “000_%a”[CR]%a “001”~”030” -----------------------1 minute to 30 minutesResponseUnacceptable “Error Code” [CR]9.11.11 CR_ON-STA CommandCommand “CR_ON-STA”[CR]Details Get Direct On setting statusAcceptable “000_%a”[CR]%a “ON” -------------------------- Direct On Start is ON“OFF” ------------------------- Direct On Start is OFFResponseUnacceptable “Error Code” [CR]9.11.12 CR_STANDBYMODE CommandCommand “CR_STANDBYMODE” [CR]Details Get Standby Mode setting statusAcceptable “000_%a”[CR]%a “ECO” -------------- Eco Mode“NORMAL” -------- Normal ModeResponseUnacceptable “Error Code” [CR]9.11.13 CR_PTIMEMODE CommandCommand “CR_PTIMEMODE”[CR]Details Get operation mode of P-timer.Acceptable “000_%a”[CR]%a “COUNTUP” ---------------- Count up is selected“COUNTDN” ---------------- Count down is selected.ResponseUnacceptable “Error code”[CR]