PLC-WK2500 Expand Serial Command Functional Specifications57 / 749.7 Input Status Read Command9.7.1 CR_INPUT CommandCommand “CR_INPUT”[CR]Details Get selected INPUT No.Acceptable “000_%1”[CR]Request data “1”-”3”ResponseUnacceptable “Error Code”[CR]9.7.2 CR_SOURCE CommandCommand “CR_SOURCE”[CR]Details Get selected SourceAcceptable “000_%1”[CR]Request data“ANALOG” ---------- Analog (RGB) Input is selected“SCART” ------------- SCART is selected“VIDEO” -------------- Video Input is selected“S-VIDEO” ----------- S-Video Input is selected“YPBPR” ------------- Component Input is selectedResponseUnacceptable “Error Code”[CR]9.7.3 CR_SRCINP1 CommandCommand "CR_SRCINP1” [CR]Details Get selected source of Input 1_CMP1Acceptable “000_%1”[CR]Request data“ANALOG” ---------- Analog RGB Input is selected“YPBPR” ----------- YPBPR Input is selected“S-VIDEO” ----------- S-Video Input is selected“SCART” ----------- Scart Input is selectedResponseUnacceptable “Error Code”[CR]9.7.4 CR_SRCINP2 CommandCommand "CR_SRCINP2” [CR]Details Get selected source of Input 2_CMP2Acceptable “000_%1”[CR]Request data “ANALOG” --------- Analog RGB Input is selected“OUT” ---------------- Monitor out is selectedResponseUnacceptable “Error Code”[CR]9.7.5 CR_SRCINP3 CommandCommand "CR_SRCINP3” [CR]Details Get selected source of Input 3_VideoAcceptable “000_%1”[CR]Request data “VIDEO” ------------- Composite Video Input is selectedResponseUnacceptable “Error Code”[CR]