C–102 Operator ManualPower SupplyThe printer requires single phase, 47 to 63 Hz. 90 to 264 VAC input power. Theprinter’s universal power supply automatically adjusts to the correct values. Afuse is provided to interrupt power to the power supply. The following tablegives typical current values.6306 Current/Wattage Requirements @ Nominal VoltageAC Volts Freq. Average Peak Average Average(RMS) (Hz) Operating Operating Idle (<5 min.) Idle (>5 min.)110 50 1.0 A/055 W 2.3 A/250 W 0.3 A/35 W 0.2 A/19 W110 60 1.0 A/105W 2.3 A/250W 0.3 A/35W 0.2 A/19 W220 50 0.5 A/105W 1.2 A/250W 0.2 A/35W 0.1 A/19W6312 Current/Wattage Requirements @ Nominal VoltageAC Volts Freq. Average Peak Average Average(RMS) (Hz) Operating Operating Idle (<5 min.) Idle (>5 min.)110 50 2.2 A/250 W 4.6 A/510 W 0.4 A/36 W 0.2 A/18 W110 60 2.2 A/250W 4.6 A/510W 0.4 A/36W 0.2 A/18 W220 50 1.1 A/250W 2.3 A/510W 0.2 A/36W 0.1 A/18WHeat Load ContributionThe average heat load contribution to the environment is approximately 735BTUs per hour (215 Watts). The minimum heat load contribution is approxi-mately 100 BTUs per hour (30 watts). The maximum is 2050 BTUs per hour(600 Watts), under continuous full-load printing conditions.Printing Conditions (110 VAC/60 Hz) Wattage BTU/HrPower On, not printing 55 W 188100% Uppercase Rolling ASCII 400W 1370Black Page Plot 600 W 2050Power Supply and Heat Load