185.2.1 HOLSTER MOUNTINGSelect proper location for mounting holster, preferably inside a storage compartment. Panel space required will be 6.5” x 8.0” (165 x203mm). Refer to Figure 5.2.1for hole dimensions. Holster can be used as template.Fig 5.2.1 Tether Operator Station Holster Hole DimensionsMaterial Use Material UseThickness Drill Thickness Drill5/64-3/32 .206 5.2 #5 3/32 .213 5.4 #31/8 .213 5.4 #3 1/8 .221 5.6 #23/16 .221 5.6 #2 3/16 .228 5.8 #1Inches mm Inches mmALUMINUM STEELHole Size Chart For Self Tapping ScrewsHole Size Hole Size5 3/4"(146 mm)2 7/8"(73 mm)7 1/4"(184 mm)5.2.2 RECEPTACLE MOUNTINGSelect proper location for mounting receptacle. Receptacle is 1-1/4” x 1-1/4” and 1/2” deep. (32 mm x 32 mm x 13 mm) Allow extraroom behind receptacle for wires. Refer to Figure 5.2.2 for hole dimensions.Fig 5.2.2Tether Operator StationReceptacle Hole DimensionsDrill (4) .098”(#40) Holes7/8”(22 mm)7/8”(22 mm)25/32”(20 mm)HOLE LAYOUTMOUNT RECEPTACLE WITH#4 SELF-TAPPING SCREWS.TIGHTEN SECURELY. INSTALLCHAIN CONNECTORUNDER SCREW HEADY5310 TETHER RECEPTACLEY5320 CLOSURE CAP5.2.3 ELECTRICAL WIRINGSee figure 5.0 for typical connections. The 4-conductor cable from the receptacle needs to be connected to power (red & black) and tothe communication link (blue & white) from the monitor. Refer to Figure 5.1.2 for typical cable preparation.Drill (3) Pilot Holes(refer to hole size chart)Mount Holster With (3)1/4-20 Self-Tapping Screws.Tighten Securely.