34Fig 6.4.1D Effects of Elevation of TrajectoryFig 6.4.1E Effects of wind on reachThis graph is approximate only.Critical applications should be tested in actual conditions to verify adequate reach.This graph shows approximately how a moderate wind can affect stream reach.0104020800 40 80 120 160 200 240 280 320 360HORIZONTAL DISTANCE (FEET)2.50 INCH TIP, 100 PSI, 1860 GPMVERTICAL DISTANCE (FEET)NO WIND20 MPH TAILWIND20 MPH HEADWIND0 25 50 75 100VERTICAL DISTANCE (M)HORIZONTAL DISTANCE (M)0204060801001201401601802000 40 80 120 160 200 240 280HORIZONTAL DISTANCE (FEET)2 .50 INCH TIP, 100 PSI, 1860 GPMVERTICAL DISTANCE (FEET)75 DEGREES60 DEGREES45 DEGREES30 DEGREES02040600 20 40 8060HORIZONTAL DISTANCE (M)VERTICAL DISTANCE (M)1 ft = 0.3048 mCURVEABCDECURVEABCDEGPMFLOW300600100015002000LPMFLOW11002300380057007500LBSREACTION1603005107601000KGFREACTION701402303404500 10 20 30 40 50 60 70 80 90METERS01020METERS010203040506070800 20 40 60 80 100 120 140 160 180 200 220 240 260 280 300HORIZONTAL DISTANCE (FEET)A BCDEMASTERSTREAM 2000, 100 PSI (7 BAR, 700 KPA)VERTICAL DISTANCE (FEET)EXCEL\MISC\RAN_MON6.4.2 MASTERSTREAM 2000 NOZZLESAutomatic nozzles maintain a constant pressure by adjusting their orifice to match the available flow. Consult the nozzle manufacturerfor maximum flow and pressure range. In all cases do not exceed 2000 gpm (7,600 LPM). TFT's Masterstream 2000 nozzle has a 300-2000 gpm flow range. Masterstream 2000 Nozzle operating instructions (Item Number LIM-030) is available on TFT's website:www.tft.com