11. Pull each cable taut. Push the cable retainershard up against the back panel. The end of thecable adjuster will pass into the hole. Tighten thescrews in the retainers so that they clamp thecables in position. Apply tension to the cables byturning the hexagonal adjusters by hand (See figure22).12. Inspect the installation of the convection boxagainst the fireplace surround. If the convection boxis aligned squarely and the sealing is satisfactory,fully tighten the cable retainers.13. If the convection box is not correctly aligned,release the tension on the cables by slackening thescrews and turning the hexagonal adjusters fullyanticlockwise. The convection box should thenautomatically realign itself. Pull each cable tautagain and push the cable retainers back against theback panel. Again, tighten the screws in theretainers and apply tension to the cables by turningthe hexagonal adjusters clockwise as far aspossible.14. Feed the free length of the cables into the gapbetween the inner and outer back panels so thatthey are available to allow easy removal andrefitting of the appliance during subsequent servicecalls. Do not cut off the free lengths of cable(See figure 22).10.3 Sealing floor front - All installations.Using the floor sealing tape supplied, seal the bottom ofthe convection box to the fireplace and hearth floor(See figure 23).Make sure that the whole length of the front edge ofthe convection box is fully sealed.© Baxi Heating U.K. Limited 2008. Page 26Figure 23. Floor SealingFigure 22. Lower cable retentionINSTALLER GUIDE