25GM 5000EAOPERATING MANUALEDITION 03/2012 ORDER NUMBER DOC 23191495.1.5 EARTHINGPerfect earthing of all conductive parts such as floors, walls, roofs, is important foroptimum coating and safety. Barriers, work pieces, transport devices, coating materialcontainer, automatic movement system or construction parts in the spray area must beconnected to the earthing system, with exception of the high-voltage parts during normaloperation.Part of the booth must be grounded in accordance with EN 12215.WARNINGDischarge of electrostatically charged components in atmospherescontaining solvents!Explosion hazard from electrostatic sparks or flames