229660 & 11260 Fire Deck Coal-Fired OvenInstallation and Operation ManualAn ongoing program of product improvement may require us to changespecifications without notice. FD-9660-CL, FD-11260-CL,Revised November 2015. Doc no: M0044.03info@woodstone-corp.com or visit woodstone-corp.comWood Stone Corporation1801 W. Bakerview Rd.Bellingham, WA 98226 USAToll Free 800.988.8103Tel 360.650.1111Fax 360.650.1166OVENS EQUIPPED FOR COAL BURNINGOvens with “-CL” in the model number are equipped to burn coal� These ovens are equipped with a blower and plenum beneath theoven that provides combustion air to the coal-fire through a grate installed in the oven deck� The coal fire must be built on this grateinside the cooking chamber of the oven� Use the blower control on the front of the oven to control the rate of air being supplied tothe coal fire by the Coal Blower Fan� As the coal burns, ash and debris will drop through the grate down into the air plenum below�To remove accumulated ash, open the Ash Chute door on the front of the oven, and using the ash rake provided with the oven�rake the ash and debris into a suitable steel container� Store the ash container in a safe place until the ash has cooled and can bedisposed of� All coal burning ovens must be vented as solid fuel equipment! See information below�USE COAL FUEL ONLY. DO NOT USE PRODUCTS NOT SPECIFIED FOR USE WITH THIS OVEN.COAL FUEL: TO ENSURE CLEANEST EMISSIONS POSSIBLE, USE ONLY HIGH QUALITY ANTHRACITE COAL. MANYVARIETIES OF COAL CONTAIN CHEMICAL IMPURITIES THAT CAN DAMAGE THE OVEN CERAMIC. USING ANTHRACITECOAL MINIMIZES THE CHANCE OF CHEMICAL DAMAGE TO THE OVEN CERAMIC. USE OF ANY COAL OTHER THANANTHRACITE COAL WILL VOID THE WARRANTY ON THE OVEN CERAMIC AND MAY LEAD TO INCREASED PARTICULATEAND OTHER EMISSIONS FROM THE OVEN WHEN COAL IS USED.CLEAN THE ASH CHUTE DAILY TO PREVENT BUILD UP OF ASH AND DEBRIS. FAILURE TO DO SO WILL RESULT INDAMAGE TO THE BLOWER UNIT AND VOID YOUR WARRANTY.DO NOT ATTEMPT TO USE THE RADIANT FLAME BURNER TO IGNITE THE COAL FIRE.COAL SHOULD BE STORED AND HANDLED IN ACCORDANCE WITH THE RECOMMENDATIONS OUTLINED IN NFPA 96.The interior floor and dome of the oven do not require creosote or soot removal� The oven flue and exhaust system will requireinspection and cleaning� The exhaust system should be inspected and cleaned per the manufacturer's and/or local code official'srecommendations�Dispose of ash per the following: place ashes into a metal container with a tight fitting lid� The closed container of ashes should beplaced on a non-combustible floor or on the ground, well away from all combustible materials, pending final disposal� They shouldbe retained in the closed container until all the cinders have thoroughly cooled� Ashes can then be disposed of safely�If at any time you feel the gas components of the oven are not operating properly, turn the oven off, shut off the gas supply and callWood Stone at 1�800�988�8103 to arrange for service�USE OF COAL OVERVIEW