6 Maintenance112 8265/8290/8365/8390 User Guide6.3 8365/8390 PERIODIC MAINTENANCEThis section describes the periodic maintenance required for this machine. This maintenance helpsensure stable image quality. In the periodic maintenance, some service parts may be checked, cleaned,or replaced. Perform periodical inspections according to the table below.N Action Frequency1 Clean wipers2 Tubing Flush and maintenance station cap flush3 Clean the edges of the caps in maintenance stationDaily maintenance4 Clean the area around the caps5 Clean around the bottom of the heads Weekly maintenance6 Replacing the sponge in the spitting box Bi-weekly maintenance7 Replacing the wipers8 Replacing upper sponge at back of the cappingstationMonthly maintenanceNotes• All cleaning in “Ink areas” must be done with Xerox 8365/8390 cleaning solution.• Above maintenance cycle is based on use:8 hours / day, 5 days / week and 44 weeks / year.If machine is used more, maintenance periods will come earlier.Available kits for the end user and their order numbers5. User and good shape kit for 6 monthsNo Description Quantity1 Sponge plate 62 Wipers 243 Spitting box sponge 124 Cleaning Liquid 250 ml 35 Instruction sheet 16 Good shape kit 16. Good shape kitNo Description Quantity1 Gloves 3002 Pipette 123 Swabs 1504 Polyknit wiper 3007. Solvent cleaning in a bottle