Initial Actions / System ChecksInitial Actions / System Checks1/981-4 88301. Ask the operator to describe the problem.2. Ask the operator to halt all print jobs and stop controller.3. Check the log book.4. Check the Recent Fault Log for trends:a. With a Controller - Print out the configuration sheet through the Utilities Menu. The last 25 faults are listed on the upper-right side of the sheet.b. Without a Controller - Enter [0391], The display will scroll through the error codes two at a time.5. Analyze the frequency of the fault codes and refer to the Status Code Entry Chart to troubleshoot the problem:a. C or E codes should occur no more frequently than once per 1000 linear feet.b. All Cutter faults should occur no more frequently than once per 10,000 linear feet.Note: E4-09, Cx-04, and Cx-05 are out-of-media codes and will occur once per 500 linear feet Also, 001 and 002 codes are power on/off. Question theoperator if the faults are excessive.6. Record the readings from the media length counter.7. Attempt to duplicate the problem.