Sensor RAPInitial Actions• This procedure can be used to check anySensor.• Ensure that the Sensor is not blocked.• Clean the Sensor surfaces before usingthis procedure.ProcedureEnter DIAGNOSTICS (General Procedures).Enter code [xxxx] to test the Sensor (Refer toappropriate BSD for the specific code). Blockthe Sensor.The Display toggles between [1] and [0].Y NThere is 4-1.4 -/+0.2 VDC at J1/P1 pin 1of the PWB.Y NThere is 4-5 +/-0.3 VDC at J1/P1 pin2 of the PWB.Y NSwitch off the power. There Isless than 2 Ohms from J1/P1pin 2 to the machine frame.Y NI Replace the PWB.Disconnect J1. There is lessthan 2 Ohms from J1/P1 pin 2 tothe machine frame.Y NCheck the wire at J1/P1 pin 1for a short circuit.If the wire is good, replace theSensor.Replace the PWB.Check the wire at J1/P1 pin 2 for anopen circuit.If the wire is good, replace the Sensor.A BA BThere is +11.5 VDC at J1 pin 1 of the PWB.Y NI Replace the PWB.Check the wire at J1/P1 pin 1 for an open circuit.If the wire is good, check the wire at J1/P1 pin 3for an open circuit.If the wire is good, replace the Sensor.Block the Sensor. The Message Display indicatesHIGH.Y NThere is +11.5 VDC at J1 pin 1 of the PWB.Y NCheck the wire at J1/P1 pin 1 for a short circuitto ground.If the wire is good, replace the Sensor.Replace the PWB.The Sensor and its circuit appear to be operating norm-ally, check the adjustment or alignment of the Sensor.Generic Sensor RAP 1/982-16 8830