Switch RAPInitial Actions• This procedure can be used to check anyswitch.ProcedureEnter DIAGNOSTICS (General Procedures).Enter code [xxxx] to test the switch (Refer toappropriate BSD for the specific code).Actuate the switchThe switch toggles from H to L or from L toH.Y NThe message display indicates LOW allthe time.Y NActuate the switch.The voltage at J1-1 (use the actualconnector/pin number from theappropriate BSD) goes to less than0.4 VDC.NCheck the wiring between theswitch and the Main PWB (A2).If the wiring is OK, replace theswitch.Replace the Main PWB (A2) (PL x.x)Replace the Switch (PL x.x)The switch and its circuit appear to beoperating normally. check the adjustment oralignment of the switch.88301/982-17 Generic Switch RAPY