9 System BackupDX100 9.3 Automatic Backup Function9-109.3.2.2 AUTO BACKUP SET Display SettingsSelect the following items on the AUTO BACKUP SET display and setvalues for the automatic backup.• RESERVE TIME BACKUP (VALID/INVALID of the cyclic backup)• BASE TIME• BACKUP CYCLE• RETRY CYCLE• MODE CHANGE BACKUP (VALID/INVALID of the backup whenswitching the mode from teach mode to play mode)• STARTUP AUTO BACKUP (VALID/INVALID of the backup when theDX 100 is started up)• SPECIFIC INPUT BACKUP (VALID/INVALID of the backup wheninputting specified signals)• UNIV.OUT NO. ON ERROR• DISPLAY AT EMERGENCY• DURING ALARM OCCURENCE• STORED FILE SETTING1. Turn ON the DX100.– If the auto backup function is already set valid, insert aCompactFlash.2. Insert a CompactFlash in the CompactFlash slot on the programmingpendant.3. Change the security mode to the management mode.4. Select {SETUP} under the main menu.NOTEWith the version in which "STORED FILE SETTING" is set-table, the capacity of a CompactFlash card inserted in theprogramming pendant is checked when the setting windowappears. Therefore, a few seconds may be needed to openthe setting window and an error may occur if no Compact-Flash is inserted.When changing the settings of "STORED FILE SETTING"or executing "ARRANGE", the files "CMOSBK.BIN" and"CMOSBK??.BIN" (?? denotes figures) in the Compact-Flash card are changed in name or deleted. If a certain fileof this type is needed to be saved before changed in nameor deleted, evacuate it into a PC, etc. beforehand.长沙工控帮教育科技有限公司工控帮助教小舒QQ:2823408167