9 System BackupDX100 9.3 Automatic Backup Function9-149.3.2.3 DX100 Status and Automatic Backup* Retry is not performed when an error occurs.* An error can be indicated by a message depending on setting. Reserve Time BackupWhile the data in the DX100 memory is being edited or overwritten, theautomatic backup is not performed at the specified backup starting timeand is suspended and retried later. To start the backup at the reservedtime, set to the time when the robot program is stopped and no job or fileis edited. Backup when Switching from Teach Mode to Play ModeWhen the mode is repeatedly switched from the teach mode to the playmode or vice versa within 1 to 2 seconds, backup starts after the last timethe mode is switched. Backup when the DX 100 starts upSince the automatic backup process is added to the DX100 start-upprocess, a few extra seconds are needed to start up the DX100.BackupTimingDX100 Status Automatic BackupCompactFlashready tosave thedataAbsence orinsufficientcapacity of theCompactFlashFrom aspecifiedstarting timeTeach mode Editing(Accessing tothe memory)Retry RetryWhen editing isinterruptedBackup ErrorPlay modeRemote modeExecuting jobs Disabled DisabledWhen stopped Backup ErrorWhen aspecifiedsignal(#40560)is inputTeach mode Editing(Accessing tothe memory)Error ErrorWhen editing isinterruptedBackup ErrorPlay modeRemote modeExecuting jobs Disabled DisabledWhen stopped Backup ErrorWhenswitching themode from theteach mode tothe play mode- Backup ErrorWhen theDX100 startsup- Backup Error长沙工控帮教育科技有限公司工控帮助教小舒QQ:2823408167