www.dadehpardazan.ir 88594014-153.3 Main Circuit Wiring3-273 Wiring and Connection3.3.3 When Using the SERVOPACK with a Single-phase 200 VPower InputSome models of -V series three-phase 200 V power input SERVOPACK can beused also with a single-phase 200 V power supply.The following models support single-phase 200 V power input.SGDV-R70A, -R90A, -1R6A, -2R8A, -5R5AWhen using the SERVOPACK with single-phase, 200 V power input, set parameterPn00B.2 to 1.(1) Parameter Setting Single-phase Power Input SelectionParameter Meaning WhenEnabledClassificationPn00Bn.0[factorysetting]Enables use of three-phase power sup-ply for three-phase SERVOPACK. After restart Setupn.1 Enables use of single-phase powersupply for three-phase SERVOPACK.WARNING• If a single-phase 200 V is input to a single-phase 200 V power input supportedSERVOPACK without having changed the setting of Pn00B.2 to 1 (single-phasepower input), the main circuit cable open phase alarm (A.F10) will be detected.• If a single-phase 200 V is input to the SERVOPACK models that do not supportsingle-phase power input, the main circuit cable open phase alarm (A.F10) will bedetected.• When using a single-phase 200 V power supply, the SERVOPACK may not beable to produce the same linear servomotor force-speed characteristics as usinga three-phase 200 V power input. Refer to the diagram of each motor force-speedcharacteristics in-V Series Product Catalog (KAEPS80000042).