www.dadehpardazan.ir 88594014-153 Wiring and Connection3.3.7 Wiring the Spring Type Main Circuit Terminal Connector3-363.3.7 Wiring the Spring Type Main Circuit Terminal ConnectorTwo types of main circuit terminals are available: a connector type and a terminalscrew type.• SERVOPACKs with terminal screws:SGDV-180A, 200A, 330A, 550A, 8R4D, 120D, 170D, 260D• SERVOPACKs with connectors:SGDV-R70F, R90F, 2R1F, 2R8F, R70A, R90A, 1R6A, 2R8A, 3R8A, 5R5A, 7R6A, 120A,1R9D, 3R5D, 5R4DA spring connector is used for SERVOPACKs with connectors.The following section describes how to wire the main circuit terminal using a con-nector. Wiring Procedure1. Remove the main circuit terminal connector from the SERVOPACK.CAUTION• Observe the following precautions when wiring main circuit terminal connectors.• For the SERVOPACKs with connectors, remove detachable main circuit terminal con-nectors from the SERVOPACK prior to wiring.• Insert only one main circuit cable per opening in the main circuit terminal connector.• Make sure that no part of the core wire comes into contact with (i.e., short-circuit)adjacent wires.Main circuitterminal connectorEnlarged ViewLock1㧚Pressthe lock.2. Remove the maincircuit terminalconnector whilepressing the lock.