Table 4.1 Keys and Displays on the LED OperatorNo. Display Name Function1 Data Display Area Displays the frequency reference, parameter number, etc.2 ESC Key Returns to the previous menu.3 RESET Key Moves the cursor to the right.Resets the drive to clear a fault situation.4 RUN Key Starts the drive.5 Up Arrow Key Scrolls up to select parameter numbers, setting values, etc.6 Down Arrow Key Scrolls down to select parameter numbers, setting values, etc.7 STOP STOP KeyStops the drive.Note: Stop priority circuit. Pressing the STOP key will alwayscause the drive to stop the motor, even when a Run command isactive at an external Run command source. Set parameter o2-06to 0 to disable the STOP key priority.8 ENTER Key Selects all modes, parameters, settings, etc.Selects a menu item to move from one display screen to the next.9 LO/RE Selection KeySwitches drive control between the operator (LOCAL) and thecontrol circuit terminals (REMOTE).Note: LOCAL/REMOTE key effective during stop in drivemode. If the digital operator could change from REMOTE toLOCAL by incorrect operation, set o2-01 (LOCAL/REMOTEKey Function Selection) to “0” (disabled) to disable LOCAL/REMOTE key.10 RUN Light Lit while the drive is operating the motor.11 LO/RE Light Lit while the operator (LOCAL) is selected to run the drive.12 ALM LED LightRefer to LED Screen Displays on page 84.13 REV LED Light14 DRV LED Light15 FOUT LED Light4.1 Using the Digital LED OperatorYASKAWA ELECTRIC TOEP C710606 47A YASKAWA AC Drive – V1000 Quick Start Guide 834 Start-Up Programming& Operation