8 - 33– +ELECLIGHTING SYSTEMYES NOEAS007892. The meter light fails to come on.YES NOYES NOHigh beam indicator lightTester positive probe → yellow 4Tester negative probe → black/white 5Meter assembly coupler• Set the main switch to “ON”.• Set the dimmer switch to “ ” or “ ”.• Measure the voltage (12 V) of green on theheadlight coupler.• Is the voltage within specification?This circuit is OK. The wiring circuitfrom the main switchto the headlight cou-pler is faulty andmust be repaired.R/W G/W Y/L Lg Y Ch Dg LR/G B/W Br/R W1. Meter light bulb and socket• Check the meter light bulb and socket forcontinuity.• Are the meter light bulb and socket OK?Replace the meterlight bulb, socket orboth.2. Voltage• Connect the pocket tester (DC 20 V) to themeter assembly coupler as shown.Tester positive probe → blue 1Tester negative probe → black/white 2• Set the main switch to “ON”.• Measure the voltage (12 V) of blue 1 onthe meter assembly coupler.• Is the voltage within specification?This circuit is OK. The wiring circuitfrom the main switchto the meter assem-bly coupler is faultyand must berepaired.R/W G/W Y/L Lg Y Ch Dg LR/G B/W Br/R W