Document: DateCreated By: ECO#LPN00541X0001A0_A 2017-11-15TMT 008502INSTALLATION INSTRUCTIONSE-BBA Serieswww.e-conolight.com | 888.243.9445 | FAX: 262.504.5409CAUTIONSIMPORTANT SAFEGUARDSWhen using electrical equipment, basic safetyprecautions should always be followed including thefollowing:READ AND FOLLOW ALLSAFETY INSTRUCTIONS1. DANGER- Risk of shock- Disconnect power beforeinstallation.DANGER – Risque de choc – Couper l’alimentationavant l’installation.2. This luminaire must be installed in accordance with theNEC or your local electrical code. If you are not familiarwith these codes and requirements, consult a qualifiedelectrician.Ce produit doit être installé conformément à NEC ou votrecode électrique local. Si vous n’êtes pas familier avec cescodes et ces exigences, veuillez contacter un électricienqualifié.3. Suitable for Wet Locations.Adspte pour les Endroits Mouiles.SAVE THESE INSTRUCTIONSFOR FUTURE REFERENCENOTES1. This carton contains fixture, anchor bolts and mountingtemplate. See reverse side for not-to-scale mountingtemplate.FOUNDATION1. Foundation should be a minimum of 12 inches (305 mm) in diam-eter, finished level and smooth, with a depth below grade of 24 (610mm) inches. NOTE: in areas where frost is imminent, consult with acivil engineer for a recommended foundation detail.2. Provided are three 3/8” diameter x 11” (352 mm) long anchor boltsand mounting template (included). Use template to set anchor boltsat proper location (Note conduit entry allowance). Anchor boltsshould project 2” (51 mm) above concrete.NOTE: Lens assembly does not need to be removed frombollard pole during installation process.1. To install bollard pole to anchor bolts, loosen four 1/4-20 set screwsat base of pole using a 1/8" Allen wrench.2. Begin lifting pole and lens assembly vertically off base. When wiringquick disconnect is exposed, unlatch two halves of quick disconnectand set pole/lens assembly aside.3. Install base plate and inner frame assembly over anchor bolts andsecure with nuts, washers, and jam nuts provided.NOTE: If leveling of the base is required, leveling nuts should beused. Do NOT use shims.4. Make electrical supply connections to terminal block on inner frameassembly. See Electrical Connection section for proper wiring.5. Reconnect two halves of quick disconnect from Step 2 and slidepole/lens assembly over interior frame and base. Be careful not topinch any lead wires.NOTE: Position pole so that 1/4-20 set screws align with circularindentations in base.6. Tighten four 1/4-20 set screws to secure pole/lens assembly to base.Fixture is equipped with universal volt driver 120-277V(ie. 120V, 208V, 240V or 277V)PHASE TO NEUTRAL WIRING 120/277V1. Connect supply ground to fixture ground (green) lead.2. Connect supply common to fixture neutral (white) lead.3. Connect supply Vin to fixture hot (black) lead.Tuck all wires carefully into wiring chamber ensuring that nowires are pinched.PHASE TO PHASE WIRING 208/240V1. Connect supply ground to fixture ground (green) lead.2. Connect supply L1 (Hot) to fixture neutral (white) lead.3. Connect supply L2 (Hot) to fixture hot (black) lead.Tuck all wires carefully into wiring chamber ensuring that nowires are pinched.CAUTION: Changes or modifications not expressly approved could voidyour authority to use this equipment.This device complies with part 15 of the FCC Rules. Operation is subjectto the following two conditions: (1) This device may not cause harmfulinterference, and (2) this device must accept any interference received,including interference that may cause undesired operation.This equipment has been tested and found to comply with the limitsfor a Class A digital device, pursuant to part 15 of the FCC Rules.These limits are designed to provide reasonable protection againstharmful interference when the equipment is operated in a commercialenvironment. This equipment generates, uses, and can radiate radiofrequency energy and, if not installed and used in accordance withthe instruction manual, may cause harmful interference to radiocommunications. Operation of this equipment in a residential areais likely to cause harmful interference in which case the user will berequired to correct the interference at his own expense.CAN ICES-003 (A)/NMB-003 (A)ELECTRICAL CONNECTIONSFCC NOTICEBOLLARD INSTALLATION