INSTALLATION INSTRUCTIONSE-MT5, E-MT6, AND E-MT7 SERIESIMPORTANT SAFEGUARDSWhen using electrical equipment, basic safety precautions shouldalways be followed including the following:READ AND FOLLOW ALLSAFETY INSTRUCTIONS1. Make certain power is OFF before starting installation orattempting any maintenance.2. Fixture comes standard with a HOT, COMMON and GROUNDwire or ground lug.3. 90°C supply wire required for E-MT5A301G. All others require60°C supply wire.4. Mounting locations above 4 feet (1.2 meters), caulking ofcanopy to mounting surface and fixture must not be usedwithout lamp shieldsSAVE THESE INSTRUCTIONSTurn off power supply to avoid the risk of electrical shock. Thisproduct must be wired in accordance with the National ElectricalCode and applicable local codes and ordinances. Proper groundingis required to ensure personal safety. A qualified electrician shoulddo all work.CAUTIONS1. Remove (3) screws connecting the pendant mounting/ballastcover to the fixture housing.2. Thread the pendant mounting cover onto the conduit.3. Complete the wiring to the power source (refer to wiringinstructions)4. Seal around the conduit using approved NEC procedures.5. If necessary, align gasket with holes in fixture housing.6. Reinsert and tighten (3) screws connecting the pendant mountingcover to the fixture housing.MOUNTING TO CONDUIT PENDANT MOUNTING(E-MTA AND E-MT6 SERIES)Document DateDrawing/Page DCR#CI308X10R1JAD 10-16208/02/10w w w. e - c o n o l i g h t . c o m 8 8 8 . 2 4 3 . 9 4 4 5 FA X : 2 6 2 . 5 0 4 . 5 4 0 91. Remove (3) screws connecting the ballast cover to the fixturehousing.2. Remove (2) screws connecting the ballast cover to theMounting Arm.3. Remove (4) screws connecting the mounting arm to the J-box.4. Attach the J-Box to the mounting surface.5. Attach conduit to J-box and pull leads to the box.6. Seal around the conduit using approved NEC procedures.7. Complete the wiring to the power source (refer towiring instructions).8. Reassemble fixture by reversing steps 1, 2 & 3.NOTE: Make sure to properly align gaskets between themounting and ballast cover and between the ballast coverand fixture when reassembling.WALL MOUNTING (E-MT7 SERIES)E-MT6A301GE-MT7A301GE-MT5A301G E-MT7F421GE-MT7M07DGE-MT7H151GE-MT6F421GE-MT6M07DGE-MT6H151GE-MT5F421GE-MT5M07DGE-MT5H151G1. Remove (3) screws connecting the ballast cover to thefixture housing.2. Remove (2) screws connecting the ballast cover to the J-box.3. Attach the J-box to the mounting surface.4. Attach conduit to J-box and pull leads to the box.5. Seal around the conduit using approved NEC procedures.6. Complete the wiring to the power source (refer towiring instructions.)7. Reassemble fixture by reversing steps 1 & 2.NOTE: Make sure to properly align gasket between the ballastcover and fixture when reassembling.CEILING MOUNTING (E-MT5 SERIES)1. Loosen guard set screws.2. Remove globe and guard assembly.3. Install recommended lamp only.4. Re-install globe and guard assembly.5. Tighten guard set screws.LAMP INSTALLATION