INSTALLATION INSTRUCTIONSFLUORESCENT WALL PACKDocument: CI308X52R0 Date: 2/1/2013Created by: TMT DCR#: 2012-071E-WPC2Error!1. This carton contains fixture, lamp, and wall mounting box.2. Review template on backside of installation sheet.NOTE: Template includes minimum mounting distance toceilings.3. Place mounting box over junction box or conduit. If mountingover junction box, a 2-1/2" inspection hole knockout isincluded. See Figure 1.4. For surface wiring (3) 1/2" threaded holes are available. SeeFigure 1.5. IMPORTANT ā Keyholes located inside box are foralignment only. Fixture is to be supported by (3) 3/16"mounting holes. Recess surrounding mounting hole willaccommodate a 1/4" bolt head. Select appropriate mountinghardware for mounting surface.6. Place a minimum of a 1/4" bead of silicone rubber on blackgasket on back of mounting box. See Figure 1a.FIGURE 1a7. Before securing fixture to wall mounting surface, make suremounting box is level.8. Secure mounting box to wall.1. Loosen (2) phillips lens screws located on the bottom of lens.Lift lens up and remove from fixture.2. Loosen (2) torx screws (use 1/4" nut driver or T-20 torx) andremove junction box cover.3. If mounting fixture over surface mounted conduit, knockoutconduit opening on either the top or sides as required. SeeFigure 2. Knockouts can be removed by using a hammer orpliers.4. Place fixture on mounting box making sure that screws onmounting box insert through keyhole opening on fixture.5. Tighten torx screws use a T-20 torx or 1/4" nut driver.6. See electrical connection instructions.7. Insert supplied lamp into socket.8. Replace glass lens by hooking hinge on top of casting andallowing lens to close. Tighten (2) phillips screwINSTALLATION OF MOUNTING BOXINSTALLATION OF FIXTUREIMPORTANT SAFEGUARDS1. RISK OF FIRE AND ELECTRICAL SHOCK. THISPRODUCT IS TO BE INSTALLED BY A QUALIFIEDELECTRICIAN ONLY.2. To avoid the possibility of electrical shock, turn off powersupply before installation or service.FIGURE 2FIGURE 1