Carrier Aquaforce 30XA Series manuals
Aquaforce 30XA Series
Table of contents
- Table Of Contents
- Table Of Contents
- SAFETY CONSIDERATIONS
- HARDWARE DESCRIPTION
- Pressure sensors
- Connections at the user terminal block
- TOUCH PILOT CONTROL INTERFACE
- Start/Stop screen
- C onfiguration.menu
- WEB CONNECTION
- TOUCH PILOT INTERFACE DETAILS
- Detailed menu description
- Alarms menu
- TOUCH PILOT CONTROL OPERATION
- Pumps control
- Control point
- Capacity limitation
- Head pressure control
- Master/slave assembly
- Variable speed fans (option 17)
- Time schedule function
- DIAGNOSTICS – TROUBLESHOOTING
- Alarm codes
Aquaforce 30XA Series
Table of contents
- REVISIONS HISTORY
- Table Of Contents
- Table Of Contents
- ABOUT THIS DOCUMENT
- INTRODUCTION
- HOW TO TRANSFORM A NON-BACNET CHILLER TO A BACNET CHILLER
- How to mount the BACnet dongle
- How to test the dongle connection
- BACNET FOR 30XAXW CHILLER
- BACNET OBJECTS
- Priority assignment
- Objects list
- BBMD configuration
- Product Description
- BACnet Interoperability Building Blocks Supported (Annex K)
- Device Management BIBBs
- Standard Object Types Supported
- Standard Object Types Supported: Analog-Input-Object
- Standard Object Types Supported: Analog-Value-Object
- Standard Object Types Supported: Binary-Input-Object
- Standard Object Types Supported: Binary-Value-Object
- Standard Object Types Supported: Device-Object
- Standard Object Types Supported: Loop
- Standard Object Types Supported: Multistate-Output-Object
- Standard Object Types Supported: Program
- Standard Object Types Supported: Trendlog Object
- Networking Options
- IP ADDRESS SETTINGS
- How to modify the unit IP address
- BACNET IP COMMUNICATION TROUBLESHOOTING
- BACNET OPC-SERVER TROUBLESHOOTING
- USB dongle not recognised
Aquaforce 30XA Series
Table of contents
- Table Of Contents
- Table Of Contents
- INTRODUCTION
- Equipment and components under pressure
- Repair safety considerations
- PRELIMINARY CHECKS
- DIMENSIONS, CLEARANCES
- XA 502 MCHE heat exchanger (standard) and 30XA 502 Cu/Al heat exchanger (option 254/255)
- XA 852-902 MCHE heat exchanger (standard) and 30XA 752-852 Cu/Al heat exchanger (option 254/255)
- Cu/Al heat exchanger (option 254/255)
- Multiple chiller installation
- PHYSICAL AND ELECTRICAL DATA FOR 30XA UNITS
- Physical data 30XA 904-1702 - standard units and units with option 119* (continued)
- Physical data 30XA 252-902 - units with option 254 and 255
- Short-circuit stability current for all units
- Electrical data
- Electrical data (continued)
- Compressor electrical data
- Electrical data, optional hydronic module
- ELECTRICAL CONNECTION
- Field control wiring
- APPLICATION DATA
- Variable flow evaporator
- Evaporator pressure drop curve
- WATER CONNECTIONS
- Victaulic water connections
- Flow control
- Pump characteristics
- FREE-COOLING OPTION (OPTION 118A)
- HEAT RECLAIM CONDENSER OPTION (OPTION 50)
- Condenser location
- Operating limits for changeover between modes
- Frost protection
- High-pressure safety switch
- Electronic expansion valve (EXV)
- MAIN OPTIONS
- STANDARD MAINTENANCE
- Tightening torques for the main electrical connections
- Evaporator maintenance
- START-UP CHECKLIST FOR 30XA LIQUID CHILLERS (USE FOR JOB FILE)