  1. H4866
  2. Table Of Contents
  3. Table Of Contents
  4. Table Of Contents
  5. Table Of Contents
  6. Table Of Contents
  7. Table Of Contents
  8. Table Of Contents
  9. Safety and Regulatory Information
  10. Electrical Hazards
  11. Labelling Summary
  12. Device-specific Safety Information
  13. System Description
  14. Block Diagram of the Point-of-Care CR 120/140
  15. Scanner Front View
  16. Scanner Left View
  17. Component Description
  18. Motion Board
  19. Sensor Board
  20. Laser Board
  21. Laser
  22. Roller Motor
  23. Linear Slide Assembly
  24. Carriage Stepper Motor
  25. Power Supply Assembly
  26. Auto-loop Key Assembly and Tray Assembly
  27. Erase Lamps
  28. Erase Lamps Inverter Assembly
  29. Erase Lamp Sensor
  30. Left Limit Sensor
  31. Screen Size Sensor
  32. Roller Sensor
  33. Z0 Sensor
  34. Top WO Sensor
  35. Service Procedures
  36. Access to Cover Screws
  37. Disconnecting the Laser
  38. Replacing the Fuses
  39. Power Inlet Module Replacement
  40. Line Filter Wire Attached to Ground
  41. USB Board Replacement
  42. Motion Board Replacement
  43. Sensor Board Replacement
  44. PM Tube and PM Board Replacement
  45. PM Assembly Screw (one side shown)
  46. Laser Board Replacement
  47. Laser Operation
  48. Roller Motor Replacement
  49. Roller Motor Drive retaining screw
  50. Operating the Roller Motor
  51. Linear Slide Assembly Replacement
  52. Stepper Motor and Left Limit Sensor Connectors
  53. Slide Assembly Attaching Screws
  54. Linear Slide Test
  55. Loader Stepper Motor Replacement
  56. Bottom of Unit
  57. Loader Assembly with Stepper Motor
  58. Power Supply Assembly Replacement
  59. Power Supply Screws on Unit Bottom
  60. Connectors on the Motion Board
  61. Main Ground Stud
  62. Erase Lamps Assembly Replacement
  63. W0 Upper Sensor Cable Connector
  64. Erase Lamp Assembly Wiring Harness
  65. Erase Lamps Inverters Replacement
  66. Inverter Attaching Screws
  67. Erase Lamps Sensors Replacement
  68. Erase Lamp Sensor Screws
  69. Left Limit Sensor Replacement
  70. Linear Motor Section of Diagnostics Screen
  71. Right Limit Sensor Replacement
  72. Screen Size Sensor Replacement
  73. Z0 Light
  74. Roller Sensor Replacement
  75. Z0 Sensor Replacement
  76. W0 Sensors Replacement (Top/Receiver and Bottom/Transmitter)
  77. W0 Top Sensor
  78. W0 Bottom Sensor
  79. Black Probe Attachment Point
  80. Screen Guide Replacement for non Auto-loop systems
  81. Remove the L Bracket
  82. Pull the Key Assembly towards you
  83. Install the New Screen Guide to the Key Assembly
  84. Rotate the Rollers Manually
  85. Auto-loop Key Assembly Replacement
  86. Release the screws securing the Auto-loop Key Assembly
  87. Pass the cable around to the Motion card (1)
  88. Auto-loop Solenoid Replacement
  89. Tray Assembly Replacement for non Auto-loop Systems
  90. Remove J513 and J514 sensors
  91. Remove the two screws retaining the black L-bracket
  92. Pull out the Key assembly
  93. Plate sides mounting screws
  94. Tray Assembly Replacement for Auto-loop Systems
  95. Remove the four screws retaining the Key assembly
  96. Calibrations
  97. New X and Y Coordinates
  98. Insert Cassette Message
  99. Position of the Dosimeter
  100. Calibration Tab
  101. Find PM Gain
  102. Calibration Successful Screen
  103. Facility Calibrations for Kodak QC Version 2.1.2/2.4.2 Software
  104. Screen Image in the Image Viewer screen
  105. Image Viewer Selections
  106. Centered Histogram
  107. Decrease PM Gain Value and Save
  108. Increase PM Gain and Save
  109. Image Appearing Four Way Split Screen in the Image Viewer
  110. Save Cv Filter Setting Screen
  111. Gain Tuning Calibration Process for Kodak QC Version 2.5
  112. Set Image and Diagnostic settings
  113. Save PM settings
  114. Adjustments
  115. Plastic gap jigs
  116. Screen Guide Adjustment (non Auto-loop)
  117. Loader Position
  118. Loosen the L Bracket screws
  119. Loader Pin and Loader Pusher Adjustments
  120. Checking Pin Height (Go)
  121. Diagnostics Screen -activate erase lamps
  122. Roller Sensor Adjustment
  123. Screen inserted between the rollers
  124. Electric Schematic Diagrams
  125. USB and Motion Schematics
  126. Sensors Schematics
  127. PM, Laser Schematics
  128. Lamps Board Schematics
  129. PS, Lamps Schematics
  130. Grounding Schematics
  131. Preventive Maintenance
  132. User Tab
  133. Removing the Protective Strips
  134. Pull Out Cleaning Plate Message
  135. Cleaning the Phosphor Screens
  136. Installing the Extraction Tool
  137. Releasing the Extraction Tool
  138. Installing the Screen
  139. Publication History