Keysight Technologies U1461A manuals
U1461A
Table of contents
- safety symbols
- safety considerations
- environmental conditions
- Table Of Contents
- Table Of Contents
- calibration overview
- adjustment is recommended
- recommended test equipment
- calibration process
- test considerations
- performance verification tests
- Performance verification tests for U1461A/U1453A
- calibration security
- unsecuring the instrument for calibration
- to change the calibration security code
- using the front panel for adjustments
- Valid adjustment input values (U1452A/U1452AT/U1451A)
- Valid adjustment input values (U1453A)
- Valid adjustment input values (U1461A)
- adjustment procedure
- Non-Contact Voltage (NCV) Calibration
- exiting the adjustment mode
- calibration count
- calibration error codes
- troubleshooting
- fuse replacement
- returning the instrument for service
- replaceable parts
- types of service available
- Obtaining Repair Service (Worldwide)
U1461A
Table of contents
- safety information
- safety symbols
- Safety Considerations
- environmental conditions
- Regulatory Markings
- Product category
- Table Of Contents
- Table Of Contents
- U1450 Series/U1461A Service Guide
- calibration interval
- Adjustment is recommended
- recommended test equipment
- Calibration Process
- Test Considerations
- Performance Verification Tests
- Performance verification tests for U1461A/U1453A
- Calibration Security
- Unsecuring the Instrument for Calibration
- To change the calibration security code
- Using the Front Panel for Adjustments
- Valid adjustment input values (U1452A/U1452AT/U1451A)
- Valid adjustment input values (U1453A)
- Valid adjustment input values (U1461A)
- Adjustment procedure
- Non-Contact Voltage (NCV) Calibration
- Exiting the adjustment mode
- Calibration Count
- Calibration Error Codes
- troubleshooting
- fuse replacement
- Returning the Instrument for Service
- replaceable parts
- Types of Service Available
- Obtaining Repair Service (Worldwide)
U1461A
Table of contents
- safety information
- safety symbols
- safety considerations
- measurement category
- environmental conditions
- Regulatory Markings
- Product category
- Table Of Contents
- Table Of Contents
- Table Of Contents
- 1 Introduction
- about this manual
- check the shipment
- Turn on your tester
- Adjust the tilt stand
- Connect to the Handheld Meter Logger Software
- Connect the Bluetooth adapter
- Your Tester in Brief
- Overview
- rotary switch
- Keypad
- display screen
- measurement units
- input terminals
- Cleaning Your Tester
- additional features
- Hazardous voltage indication
- 2 Making Measurements
- Insulation Resistance Test
- Using the Remote Switch Probe
- Locking the test
- Timed (T) insulation resistance/earth-bond resistance test
- Measuring the Dielectric Absorption Ratio (DAR)
- Measuring the Polarization Index (PI)
- Viewing the leakage current
- Performing stepped voltage trip tests
- Changing the insulation resistance test voltage
- Earth-Bond Resistance Test
- measuring ac or dc voltage
- Auto AC or DC signal identification
- Using the LPF (Low Pass Filter) feature for AC signals
- Enabling the LPF in the Setup
- measuring ac or dc current
- measuring frequency
- Measuring duty cycle and pulse width
- measuring resistance
- continuity test
- diode test
- Using the Auto-diode feature
- measuring capacitance
- Viewing the cable length value
- measuring temperature
- Non-Contact AC Voltage Detection (Vsense)
- Making Relative Measurements (Null)
- Capturing Maximum and Minimum Values (Max Min)
- Freezing the Display (TrigHold and AutoHold)
- Performing Limit Comparisons (Limit)
- Recording Measurement Data (Log)
- Performing manual logs (HAND)
- Performing event logs (TRIG)
- Reviewing Previously Recorded Data (View)
- 4 Setup Options
- using the setup menu
- editing numerical values
- setup menu summary
- setup menu items
- Menu
- changing the beep frequency
- changing the baud rate
- specifications