Chapter 2. CLI Syntax Reference119 3ware SAS/SATA RAID Controller CLI Guide, Version 9.5.2/cx/bbu showattribute [attribute ...]This command shows the current setting of the given attribute(s) on the BBUboard. One or many attributes can be specified. Specifying an invalid attributewill terminate the loop. Possible attributes are: batinst, bootloader, cap, fw,lasttest, pcb, ready, status, serial, temp, volt./cx/bbu show batinstThis command shows the date when the current battery was installed./cx/bbu show bootloaderThis command shows the BBU's boot loader version./cx/bbu show capThis command shows the battery capacity in hours.A value of '0 hours' will be displayed if the battery capacity test has neverbeen run./cx/bbu show fwThis command shows the BBU firmware version number./cx/bbu show lasttestThis command shows the date the battery capacity was last measured. If thebattery capacity test has never been run, then 'xx-xxx-xxxx' will be displayed./cx/bbu show pcbThis command shows the PCB revision number on the BBU.Note: The estimated BBU capacity hours displayed is based on the measurementtaken during the last test. If you have not run the BBU test command for some time,this number can be misleading. You can use the command /cx/bbu show lasttestto check the date of the last test. For information about running a test, see “/cx/bbutest [quiet]” on page 122.Note: The estimated BBU capacity hours displayed is based on the measurementtaken during the last test. If you have not run the BBU test command for some time,this number can be misleading. For information about running a test, see “/cx/bbutest [quiet]” on page 122.